|  | | Clean room furnace
- Chamber furnace for heat treatment of metal or ceramic work pieces
- Over centre clamps secure the door to a steel surround, creating both thermal and gas seals, which prevent pressurised clean room air leaking into the furnace chamber
- The insulated door opens outwards and sideways via a central pivot support, keeping the hot face away from the operator
- Chamber dimensions: 460mm high x 460mm wide x 1060mm deep
- Maximum temperature 1200°C, maximum recommended continuous operating temperature 1150°C
- Element type: resistance wire coils supported in grooves in two side walls
- Insulation: low thermal mass insulation combined with refractory brick hearth tile to support the load
- Two zone temperature contol via dual display PID temperature controller/programmer with sixteen segments (type Eurotherm 2408CG) plus overtemperature alarm (type Eurotherm 2116)
- Type R thermocouple
- 415-240 volts three phase with neutral, 25A per phase, 16kW
|
| |
|
  |